Missouri / Ripley County
Score 23 · moderate · #104 of 113 in MO
Crawl space moisture in Ripley County, MO
Ripley County scores moderate: no single wet-soil signal dominates its mapped acres. Where a seasonal water table is reported — 34% of acres — it averages 1.8 ft below grade, shallow enough to reach a typical crawl-space footing.
- 1Water table 1.8 ft
- 2Wet soils 7%
- 3Moisture score 23
- 4EPA radon zone 2
Reading the Ripley County soil survey
The score of 23 combines four parts, each from the USDA survey: wet drainage classes contribute 15.1 points of 100 on their own scale, group D soils 40.6, a shallow water table 24.5, and flooding 11.4; the weights are on the methodology page. The dominant hydrologic group is B (29% of acres): moderate infiltration.
A water table under two feet is the single most important number here. A crawl-space floor is usually 18 to 36 inches below the joists and often below outside grade, so in a wet season groundwater can stand at or above the crawl-space floor on the soils that report a water table — about 34% of Ripley County's acres. Venting cannot fix that; it needs drainage — a perimeter drain to daylight or a sump — before any liner goes down.
Ripley County against the rest of Missouri
Ripley County ranks 104 of 113 Missouri counties, 16 points below the state median of 39. That places it in the middle range, nationally and for the state. Statewide, 32% of mapped soil is in the wet drainage classes; here it is 7%, below the state figure — the score here comes from flooding and ponding rather than drainage class alone. After well drained, the next most common class is somewhat excessively drained at 30%.
Flooding. 1.2% of acres with a flooding class are rated frequent; 16.1% of acres with a flooding class are rated occasional; 3% of acres with a flooding class are rated rare. That is a large flood-prone share; a crawl space in the floodplain needs flood vents under most local floodplain ordinances, which is a separate rule from R408 and can rule out a fully sealed design.
What it means for a crawl space here
In a moderate county the soil record is mixed rather than uniformly wet, so conditions vary from lot to lot. Where the lot drains, the model-code default — a vented crawl space with 1 sq ft of net vent per 150 sq ft of floor, or 1 per 1500 with a Class I vapor retarder on the ground — is a reasonable starting point; where the sections above point to a shallow water table or flood-prone soil on your lot, plan as for an elevated county. Either way, check the site first: grading that falls away from the foundation, gutters and downspouts that discharge well clear of it, and a ground cover over bare earth. A wet crawl space in a moderate county points to one of those first.
Radon. EPA radon zone 2. The zone is a county-level prediction; EPA says elevated levels occur in every zone and every home should be tested.
Near Ripley County by score
Sources: USDA NRCS SSURGO via Soil Data Access (muaggatt: drclassdcd, hydgrpdcd, flodfreqdcd, pondfreqprs, wtdepannmin), acreage-weighted (survey area MO181; drainage covers 100% of 404,243 mapped acres); EPA Map of Radon Zones, county table (June 2024 JSON); IRC R408.3 Unvented crawl space, as adopted in S.C. Code Regs. 8-1221 (LII). Checked 2026-10-23.